| 4.1 Main Parameters and Technical Performance | Specification | RS71B (NGT0) |
| Domestic and Foreign Equivalent Models | RS31 HLS00 |
| Rated Current (A) | 25, 32, 40, 50, 63, 80 100, 125, 160 |
| Rated Voltage (V) | AC380, AC400, AC500 AC660, AC690, AC800 |
| Breaking Capacity (kA) | 100 |
| Notes | |
| Specification | RS711 (NGT1) |
| Domestic and Foreign Equivalent Models | RS32 RS6-1 |
| Rated Current (A) | 50, 63, 80, 100 125, 160 100, 125, 160 180, 200, 250 |
| Rated Voltage (V) | DC220, DC250, DC500 DC600, DC750, DC800 AC380, AC400, AC500, AC660, AC690, AC800 AC1000 |
| Breaking Capacity (kA) | 50 100 |
| Notes | No need to use base (bolt connection, directly connected to the circuit) |
| Specification | RS712 (NGT2) |
| Domestic and Foreign Equivalent Models | RS33 RS6-2 |
| Rated Current (A) | 200, 250, 280 315, 350, 400 |
| Rated Voltage (V) | AC380, AC400, AC500 AC660, AC690, AC800 AC1000 |
| Breaking Capacity (kA) | 100 |
| Notes | |
| Specification | RS713 (NGT3) |
| Domestic and Foreign Equivalent Models | RS34 RS6-3 |
| Rated Current (A) | 200, 250, 280 315, 355, 400 450, 500, 560 630 |
| Rated Voltage (V) | AC380, AC400, AC500 AC660, AC690, AC800 AC1000 |
| Breaking Capacity (kA) | 100 |
| Notes | |
| Specification | RS714 (NGT4) |
| Domestic and Foreign Equivalent Models | RS39 |
| Rated Current (A) | 700, 800, 900 1000, 1250 |
| Rated Voltage (V) | AC380, AC400, AC500 AC660, AC690, AC800 AC1000 |
| Breaking Capacity (kA) | 100 |
| Notes | |
| 4.2 Main Parameters and Technical Performance of RS71C(NGTC) Series Fuse | Specification | RS711BC (NGTC00) |
| Base Model Used | RT36-00 (NT00) |
| Domestic and Foreign Equivalent Models | RS31 |
| Rated Current (A) | 25, 32, 40, 50, 63, 80 100, 125, 160 |
| Rated Voltage (V) | AC380, AC400, AC500 AC660, AC690, AC800 |
| Breaking Capacity (kA) | 100 |
| Notes | |
| Specification | RS711C (NGTC1) |
| Base Model Used | RT36-1 (NT1) |
| Domestic and Foreign Equivalent Models | RS32 |
| Rated Current (A) | 100, 125, 160 180, 200, 250 |
| Rated Voltage (V) | AC380, AC400, AC500 AC660, AC690, AC800 AC1000 |
| Breaking Capacity (kA) | 100 |
| Notes | |
| Specification | RS712C (NGTC2) |
| Base Model Used | RT36-2 (NT2) |
| Domestic and Foreign Equivalent Models | RS33 |
| Rated Current (A) | 200, 250, 280 315, 350, 400 |
| Rated Voltage (V) | AC380, AC400, AC500 AC660, AC690, AC800 AC1000 |
| Breaking Capacity (kA) | 100 |
| Notes | Dimensions are the same as RT36 series fuses |
| Specification | RS713C (NGTC3) |
| Base Model Used | RT36-3 (NT3) |
| Domestic and Foreign Equivalent Models | RS34 |
| Rated Current (A) | 200, 250, 280 315, 355, 400 450, 500, 560 630 |
| Rated Voltage (V) | AC380, AC400, AC500 AC660, AC690, AC800 AC1000 |
| Breaking Capacity (kA) | 100 |
| Remarks | |
| Specification | RS714C (NGTC4) |
| Compatible Base Model | RT36-4 |
| Domestic and Foreign Equivalent Models | RS39 |
| Rated Current (A) | 700, 800, 900 1000, 1250 |
| Rated Voltage (V) | AC380, AC400, AC500 AC660, AC690, AC800 AC1000 |
| Breaking Capacity (kA) | 100 |
| Remarks | |