| Electrical Characteristics | Model | NXZBN-63S, NXZBN-63H |
| Actuator | NXB-63, NXB-63H |
| Frame Current (A) | 63, 63 |
| Rated Working Current Ie (A) | 10, 16, 20, 25, 32, 40, 50, 63, 10, 16, 20, 25, 32, 40, 50, 63 |
| Rated Working Voltage Ue (V) | AC400V/AC415V, 50Hz/60Hz (2P product AC230V/AC240V, 50Hz/60Hz), AC400V/AC415V, 50Hz/60Hz (2P product AC230V/AC240V, 50Hz/60Hz) |
| Rated Impulse Withstand Voltage Uimp (kV) | 4, 4 |
| Rated Insulation Voltage Ui (V) | 500, 500 |
| Usage Category | AC-33IB: 10, 16, 20, 25, 32, 40, 50, 63A; AC-33B: 10, 16, 20, 25, 32, 40, 50, 63A; AC-33IB: 10, 16, 20, 25, 32, 40, 50, 63A; AC-33B: 10, 16, 20, 25, 32, 40, 50, 63A |
| Poles | 2P, 3P, 4P, 2P, 3P, 4P |
| Rated Short-Circuit Making Capacity Icm (kA) | 9.18, 17 |
| Rated Short-Circuit Breaking Capacity Icn (kA) | 6, 10 |
| Tripping Curve Type | C, D, C, D |
| Mechanical Life (Times) | 10000, 10000 |
| Electrical Life (Times) | 3000, 3000 |
| Controller Characteristics | Controller Model | A: Basic Type, B: Standard Type, D: Intelligent Type, E: Special Type, A: Basic Type, B: Standard Type, D: Intelligent Type, E: Special Type |
| Toucher Switching Time (s) | ≤ 0.9, ≤ 0.5 |
| Switching Action Time (s) | ≤ 1.5, ≤ 1.0 |
| Controller Installation Method | Integral Type, Integral Type |
| Rated Impulse Withstand Voltage Uimp (kV) | 2.5, 2.5 |
| Rated Control Power Supply Voltage Us (V) | AC230V/240V, 50Hz/60Hz, AC230V/240V, 50Hz/60Hz |
| Control Voltage Range | 85%Us~110%Us, 85%Us~110%Us |
| Electrical Characteristics | Model | NXZHBN-63, NXZHBN-125 |
| Frame Current (A) | 63, 125 |
| Rated Working Current Ie (A) | 10, 16, 20, 25, 32, 40, 50, 63, 20, 32, 40, 63, 80, 100, 125 |
| Rated Working Voltage Ue (V) | AC400V/AC415V, 50Hz/60Hz (2P product AC230V/AC240V, 50Hz/60Hz), AC400V/AC415V, 50Hz/60Hz (2P product AC230V/AC240V, 50Hz/60Hz) |
| Rated Impulse Withstand Voltage Uimp (kV) | 4, 6 |
| Rated Insulation Voltage Ui (V) | 690, 500 |
| Usage Category | AC-33IB: 10, 16, 20, 25, 32, 40, 50, 63A; AC-33B: 10, 16, 20, 25, 32, 40, 50, 63A; AC-32IB: 20, 32, 40, 63, 80, 100, 125A; AC-33IB: 20, 32, 40, 63A; AC-33IB: 10, 16, 20, 25, 32, 40, 50, 63A; AC-33B: 20, 32, 40, 63A |
| Poles | 2P, 3P, 4P, 2P, 3P, 4P |
| Rated Limiting Short-Circuit Current Iq (kA) | 100, 100 |
| Mechanical Life (Times) | 10000, 10000 |
| Electrical Life (Times) | 1500, 1500 |
| Controller Characteristics | Controller Model | A: Basic Type, B: Standard Type, D: Intelligent Type, E: Special Type, A: Basic Type, B: Standard Type, D: Intelligent Type, E: Special Type |
| Toucher Switching Time (s) | ≤ 0.9, ≤ 0.5 |
| Switching Action Time (s) | ≤ 1.5, ≤ 1.0 |
| Controller Installation Method | Integral Type, Integral Type |
| Rated Impulse Withstand Voltage Uimp (kV) | 2.5, 2.5 |
| Rated Control Power Supply Voltage Us (V) | AC230V/240V, 50Hz/60Hz, AC230V/240V, 50Hz/60Hz |
| Control Voltage Range | 85%Us~110%Us, 85%Us~110%Us |