| Model Specification | NXZN-80 |
| Rated Operating Current Ie(A) | 10、16、20、25、32 |
| Rated Insulation Voltage Ue(V) | 800 |
| Rated Impact Voltage Uimp(kV) | 8 |
| Usage Category | AC-33B |
| Number of Poles | 2P、3P、4P |
| Rated Limiting Short Circuit Current Iq(kA)(with SCPD) | 100 |
| Rated Short Circuit Closing Capacity Icm(kA) | - |
| Rated Short Time Withstand Current Icw(kA) | - |
| Contact Action Time(s) | ≤0.8 |
| Transfer Action Time(s) | ≤1.6 |
| Mechanical Life (Times) | 10000 |
| Electrical Life (Times) | 3000 |
| Switch Position | Power I、Power II、Off Position |
| Wiring Method | Top In Bottom Out, Side Same Inlet |
| Overall Dimensions (mm) Max | 162×92×88 |
| Pole Spacing | 18 |
| Controller Model | A(Basic Type)、AW(Active Output Basic Type)、B(Standard Type)、BW(Active Output Standard Type) |
| Controller Installation Method | Integral Type |
| Rated Control Power Supply Voltage Us(V) | AC230V/240V,50Hz/60Hz |
| Model Specification | NXZN-125 |
| Rated Operating Current Ie(A) | 10、16、20、25、32、40、50、63、80 |
| Rated Insulation Voltage Ue(V) | 800 |
| Rated Impact Voltage Uimp(kV) | 8 |
| Usage Category | AC-33B |
| Number of Poles | 3P、4P |
| Rated Limiting Short Circuit Current Iq(kA)(with SCPD) | 100 |
| Rated Short Circuit Closing Capacity Icm(kA) | 7.65 |
| Rated Short Time Withstand Current Icw(kA) | 5/30ms |
| Contact Action Time(s) | ≤0.6 |
| Transfer Action Time(s) | ≤1.5 |
| Mechanical Life (Times) | 10000 |
| Electrical Life (Times) | 3000 |
| Switch Position | Power I、Power II、Off Position |
| Wiring Method | Top In Bottom Out, Side Same Inlet |
| Overall Dimensions (mm) Max | 210×125×108 |
| Pole Spacing | 25 |
| Controller Model | A(Basic Type)、AW(Active Output Basic Type)、B(Standard Type)、BW(Active Output Standard Type) |
| Controller Installation Method | Integral Type |
| Rated Control Power Supply Voltage Us(V) | AC230V/240V,50Hz/60Hz |
| Model Specification | NXZN-250 |
| Rated Operating Current Ie(A) | 10、16、20、25、32、40、50、63、80、100、125 |
| Rated Insulation Voltage Ue(V) | 800 |
| Rated Impact Voltage Uimp(kV) | 8 |
| Usage Category | AC-33B |
| Number of Poles | 3P、4P |
| Rated Limiting Short Circuit Current Iq(kA)(with SCPD) | 100 |
| Rated Short Circuit Closing Capacity Icm(kA) | 17 |
| Rated Short Time Withstand Current Icw(kA) | 10/30ms |
| Contact Action Time(s) | ≤0.6 |
| Transfer Action Time(s) | ≤1.6 |
| Mechanical Life (Times) | 10000 |
| Electrical Life (Times) | 1500 |
| Switch Position | Power I、Power II、Off Position |
| Wiring Method | Top In Bottom Out, Side Same Inlet |
| Overall Dimensions (mm) Max | 260×168×141.5 |
| Pole Spacing | 35 |
| Controller Model | A(Basic Type)、AW(Active Output Basic Type)、B(Standard Type)、BW(Active Output Standard Type) |
| Controller Installation Method | Integral Type |
| Rated Control Power Supply Voltage Us(V) | AC230V/240V,50Hz/60Hz |
| Model Specification | NXZN-400 |
| Rated Operating Current Ie(A) | 80、100、125、140、150、160、200、225、250、315、350、400 |
| Rated Insulation Voltage Ue(V) | d> | 800 |
| Rated impulse voltage Uimp(kV) | 8 |
| Usage category | AC-33B |
| Poles | 3P、4P |
| Rated limited short-circuit current Iq(kA)(with SCPD) | 100 |
| Rated short-circuit making capacity Icm(kA) | 52.5 |
| Rated short-time withstanding current Icw(kA) | 25/60ms |
| Contact closing time(s) | ≤0.8 |
| Transfer operation time(s) | ≤2.4 |
| Mechanical life (times) | 6000 |
| Electrical life (times) | 1000 |
| Switch position | Power I, Power II, Off position |
| Wiring method | Top in bottom out, side same in line |
| Overall dimensions width×height×depth(mm)Max | 392×262×203 |
| Pole spacing | 58 |
| Controller model | A (basic type), AW (passive output basic type), B (standard type), BW (passive output standard type) |
| Controller installation method | Integral type |
| Rated control power supply voltage Us(V) | AC230V/240V, 50Hz/60Hz |
| Model specification | NXZN-630 |
| Rated working current Ie(A) | 160, 200, 250, 315, 350, 400, 500, 630 |
| Rated insulation voltage Ue(V) | 800 |
| Rated impulse voltage Uimp(kV) | 8 |
| Usage category | AC-33B |
| Poles | 3P、4P |
| Rated limited short-circuit current Iq(kA)(with SCPD) | 100 |
| Rated short-circuit making capacity Icm(kA) | 52.5 |
| Rated short-time withstanding current Icw(kA) | 25/60ms |
| Contact closing time(s) | ≤0.8 |
| Transfer operation time(s) | ≤2.4 |
| Mechanical life (times) | 6000 |
| Electrical life (times) | 1000 |
| Switch position | Power I, Power II, Off position |
| Wiring method | Top in bottom out, side same in line |
| Overall dimensions width×height×depth(mm)Max | 392×262×203 |