NXZN Series Automatic Transfer Switch Electrical Equipment (PC Level)

Product category:
Automatic Transfer Switch (ATS)
Product code:
P-657
Model:
NXZN

Function & Use (Application Scenarios)

Switching electrical equipment, automatic transfer switch products are mainly applicable to the same side incoming lines, small volume, suitable for engineering support, installation and maintenance, and long-term stable operation, meeting the on-site application needs of electrical systems.

Surprise on inquiry

Product highlights

  • Smart Communication Support
  • Energy-efficient and efficient operation
  • Control response is stable
  • Engineering Application Compatibility
  • Stable and reliable operation

Model

NXZN

Main Product Parameters

CategoryOther (Tools / Labor Protection / Machining Equipment)Secondary CategoryAutomatic Transfer Switch
ParametersFrame current: 80/125/250/630; Usage category: AC-33iB (16A~630A); AC-33B (16A~350A); Pole number: 2P/3P/4P; Wiring method: Same side input, two in one out; Controller type: A (Standard type), B (Intelligent type)Advantages/Core Features01 Flexible and convenient; all series use the same side wiring design, saving 20% in material costs and improving wiring efficiency by 30%; using a new technology platform, the 80 frame size is reduced by 60%, and the 125/250 frame size is reduced by 30%, greatly saving cabinet space; 02 Safe and reliable; the switch uses a three-stage pre-energy storage design, with contacts capable of opening/closing within 10ms, and the contact switching speed is independent of manual operation, resulting in a longer product life and safer operation; the 125~630 frame size features humanized anti-misassembly design and small-angle mechanism design; manual operation is not possible in automatic mode, ensuring user safety; 03 Excellent performance; using a flexible rotating contact system, the usage category is up to AC-33B, which can cope with motor load or high inductive load current impact, expanding the application scenarios; it has functions such as over-voltage/under-voltage, fire protection, grid-generator, and can be flexibly configured according to different needs.

Product details

Function and Purpose

Same-side wiring, compact size;

Detailed Description

Parameters:
Frame Current: 80/125/250/630
Usage Category: AC-33iB (16A~630A); AC-33B (16A~350A)
Pole Number: 2P/3P/4P
Wiring Method: Same-side wiring, two in one out
Controller Type: A (Standard Type), B (Intelligent Type)

Advantages/Core Features:
01 Flexible and Convenient
All series use same-side wiring design, saving 20% material cost and improving wiring efficiency by 30%

Using a new technology platform, the 80 frame size is reduced by 60%, and the 125/250 frame size is reduced by 30%, greatly saving cabinet space
02 Safe and Reliable
The switch uses a three-stage pre-energy storage design, achieving opening and closing within 10ms, and the contact switching speed is independent of manual operation, resulting in longer product life and safer operation

125~630 frame uses humanized anti-mistake design and small-angle mechanism design; manual operation is not possible in automatic mode, ensuring user safety
03 Excellent Performance
Adopting a flexible rotating contact system, the highest usage category is AC-33B, which can cope with motor load or high inductive load current impact, expanding the application scenarios

It has functions such as over-voltage, under-voltage, fire protection, grid-generator, etc., and can be flexibly configured according to different needs

Details

Parameter CategoryParameter ItemParameter Value
Model SpecificationNXZN-80
Rated Operating Current Ie(A)10、16、20、25、32
Rated Insulation Voltage Ue(V)800
Rated Impact Voltage Uimp(kV)8
Usage CategoryAC-33B
Number of Poles2P、3P、4P
Rated Limiting Short Circuit Current Iq(kA)(with SCPD)100
Rated Short Circuit Closing Capacity Icm(kA)-
Rated Short Time Withstand Current Icw(kA)-
Contact Action Time(s)≤0.8
Transfer Action Time(s)≤1.6
Mechanical Life (Times)10000
Electrical Life (Times)3000
Switch PositionPower I、Power II、Off Position
Wiring MethodTop In Bottom Out, Side Same Inlet
Overall Dimensions (mm) Max162×92×88
Pole Spacing18
Controller ModelA(Basic Type)、AW(Active Output Basic Type)、B(Standard Type)、BW(Active Output Standard Type)
Controller Installation MethodIntegral Type
Rated Control Power Supply Voltage Us(V)AC230V/240V,50Hz/60Hz
Model SpecificationNXZN-125
Rated Operating Current Ie(A)10、16、20、25、32、40、50、63、80
Rated Insulation Voltage Ue(V)800
Rated Impact Voltage Uimp(kV)8
Usage CategoryAC-33B
Number of Poles3P、4P
Rated Limiting Short Circuit Current Iq(kA)(with SCPD)100
Rated Short Circuit Closing Capacity Icm(kA)7.65
Rated Short Time Withstand Current Icw(kA)5/30ms
Contact Action Time(s)≤0.6
Transfer Action Time(s)≤1.5
Mechanical Life (Times)10000
Electrical Life (Times)3000
Switch PositionPower I、Power II、Off Position
Wiring MethodTop In Bottom Out, Side Same Inlet
Overall Dimensions (mm) Max210×125×108
Pole Spacing25
Controller ModelA(Basic Type)、AW(Active Output Basic Type)、B(Standard Type)、BW(Active Output Standard Type)
Controller Installation MethodIntegral Type
Rated Control Power Supply Voltage Us(V)AC230V/240V,50Hz/60Hz
Model SpecificationNXZN-250
Rated Operating Current Ie(A)10、16、20、25、32、40、50、63、80、100、125
Rated Insulation Voltage Ue(V)800
Rated Impact Voltage Uimp(kV)8
Usage CategoryAC-33B
Number of Poles3P、4P
Rated Limiting Short Circuit Current Iq(kA)(with SCPD)100
Rated Short Circuit Closing Capacity Icm(kA)17
Rated Short Time Withstand Current Icw(kA)10/30ms
Contact Action Time(s)≤0.6
Transfer Action Time(s)≤1.6
Mechanical Life (Times)10000
Electrical Life (Times)1500
Switch PositionPower I、Power II、Off Position
Wiring MethodTop In Bottom Out, Side Same Inlet
Overall Dimensions (mm) Max260×168×141.5
Pole Spacing35
Controller ModelA(Basic Type)、AW(Active Output Basic Type)、B(Standard Type)、BW(Active Output Standard Type)
Controller Installation MethodIntegral Type
Rated Control Power Supply Voltage Us(V)AC230V/240V,50Hz/60Hz
Model SpecificationNXZN-400
Rated Operating Current Ie(A)80、100、125、140、150、160、200、225、250、315、350、400
Rated Insulation Voltage Ue(V)d>800
Rated impulse voltage Uimp(kV)8
Usage categoryAC-33B
Poles3P、4P
Rated limited short-circuit current Iq(kA)(with SCPD)100
Rated short-circuit making capacity Icm(kA)52.5
Rated short-time withstanding current Icw(kA)25/60ms
Contact closing time(s)≤0.8
Transfer operation time(s)≤2.4
Mechanical life (times)6000
Electrical life (times)1000
Switch positionPower I, Power II, Off position
Wiring methodTop in bottom out, side same in line
Overall dimensions width×height×depth(mm)Max392×262×203
Pole spacing58
Controller modelA (basic type), AW (passive output basic type), B (standard type), BW (passive output standard type)
Controller installation methodIntegral type
Rated control power supply voltage Us(V)AC230V/240V, 50Hz/60Hz
Model specificationNXZN-630
Rated working current Ie(A)160, 200, 250, 315, 350, 400, 500, 630
Rated insulation voltage Ue(V)800
Rated impulse voltage Uimp(kV)8
Usage categoryAC-33B
Poles3P、4P
Rated limited short-circuit current Iq(kA)(with SCPD)100
Rated short-circuit making capacity Icm(kA)52.5
Rated short-time withstanding current Icw(kA)25/60ms
Contact closing time(s)≤0.8
Transfer operation time(s)≤2.4
Mechanical life (times)6000
Electrical life (times)1000
Switch positionPower I, Power II, Off position
Wiring methodTop in bottom out, side same in line
Overall dimensions width×height×depth(mm)Max392×262×203

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.