BH-0.66 Ⅲ Type Current Transformer

Product category:
Current transformer
Product code:
P-601
Model:

Function & Use (Application Scenarios)

Power electrical appliances, current transformers are mainly suitable for indoor use, with a maximum equipment voltage of 0.72kV and below, load power factor of 0.8, and rated frequency of 50Hz AC circuits for current and energy measurement or metering. They use busbar fixation or base plate fixation.

Surprise on inquiry

Product highlights

  • Easy installation and maintenance
  • Accurate meter monitoring
  • Engineering Application Compatibility
  • Stable and reliable operation
  • Easy system integration

Model

Main Product Parameters

CategoryInstrument transformerSecondary CategoryCurrent Transformer

Product details

Function and Use

The BH-0.66 III type current transformer is used indoors, with a maximum equipment voltage of 0.72kV or less, load power factor of 0.8, and rated frequency of 50Hz in AC circuits for current and energy measurement or metering. It is installed by busbar fixation or base plate fixation. The transformer has a window in the middle for busbar or cable passage. Compared with Type I and Type II, it has fewer accessories and is easier to install.

Detail Parameters

Parameter Table 1

Parameter CategoryParameter ItemParameter Value
Frame ModelBH-0.66 20 III
Current Ratio A75/52.5
100/52.5
150/55
200/55
75/12.5
100/12.5
150/15
Rated Output VA
Number of Winding Turns1
Dimensions and Installation Size
Frame ModelBH-0.66 30 III
Current Ratio A150/55
200/510
250/510
300/510
400/510
500/510
150/15
200/15
250/15
300/15
400/15
Rated Output VA
Number of Winding Turns1
Dimensions and Installation Size
Frame ModelBH-0.66 40 III
Current Ratio A150/55
200/510
250/510
300/510
400/510
500/510
600/510
750/510
800/510
1000/510
150/15
200/15
250/110
300/110
400/110
500/110
600/110
750/110
800/110
Rated Output VA
Number of Winding Turns1
Dimensions and Installation Size

Parameter Table 2

/tr>
Parameter CategoryParameter ItemParameter Value
BH-0.66 50 IIIRated Voltage300/5
Rated Current10
Accuracy Class10
Accuracy Level1
Rated Voltage400/5
Rated Current10
Accuracy Class10
Accuracy Level1
Rated Voltage500/5
Rated Current10
Accuracy Class10
Accuracy Level5
Rated Voltage600/5
Rated Current10
Accuracy Class10
Accuracy Level5
Rated Voltage750/5
Rated Current10
Accuracy Class10
Accuracy Level5
Rated Voltage800/5
Rated Current10
Accuracy Class10
Accuracy Level5
Rated Voltage1000/5
Rated Current10
Accuracy Class10
Accuracy Class5
Rated Voltage1200/5
Rated Current20
Accuracy Class20
Accuracy Class5
Rated Voltage300/1
Rated Current10
Accuracy Class5
Accuracy Class1
Rated Voltage400/1
Rated Current10
Accuracy Class10
Accuracy Class1
Rated Voltage500/1
Rated Current10
Accuracy Class10
Accuracy Class1
Rated Voltage600/1
Rated Current10
Accuracy Class10
Accuracy Class5
Rated Voltage750/1
Rated Current10
Accuracy Class10
Accuracy Class5
Rated Voltage800/1
Rated Current10
Accuracy Class10
Accuracy Class5
Rated Voltage1000/1
Rated Current10
Accuracy Class10
Accuracy Class1
BH-0.66 60 IIIRated Voltage500/5
Rated Current10
Accuracy Class10
Accuracy Class1
Rated Voltage600/5
Rated Current10
Accuracy Class10
Accuracy Class1
Rated Voltage750/5
Rated Current10
Accuracy Class10
Accuracy Class5
Rated Voltage800/5
Rated Current10
Accuracy Class10
Accuracy Class5
Rated Voltage1000/5
Rated Current10
Accuracy Class10
Accuracy Class5
Rated Voltage1200/5
Rated Current20
Accuracy Class20
Accuracy Class5
Rated Voltage1500/5
Rated Current20
Accuracy Class20
Accuracy Class10
Rated Voltage2000/5
Rated Current30
Accuracy Class30
Accuracy Class10
Rated Voltage500/1
Rated Current10
Accuracy Class10
Accuracy Class1
Rated Voltage600/1
Rated Current10
Accuracy Class10
Accuracy Class1
Rated Voltage750/1
Rated Current10
Accuracy Class10
Accuracy Class1
Rated Voltage800/1
Rated Current10
Accuracy Class10
Accuracy Class1
Rated Voltage1000/1
Rated Current10
Accuracy Class10
Precision Level5
Rated Voltage1200/1
Rated Current20
Accuracy Class20
Precision Level20
Rated Voltage1500/1
Rated Current20
Accuracy Class20
Precision Level10
Rated Voltage2000/1
Rated Current30
Accuracy Class30
Precision Level5
BH-0.66 80 IIIRated Voltage500/5
Rated Current10
Accuracy Class10
Precision Level1
Rated Voltage600/5
Rated Current10
Accuracy Class10
Precision Level1
Rated Voltage750/5
Rated Current10
Accuracy Class10
Precision Level1
Rated Voltage800/5
Rated Current10
Accuracy Class10
Precision Level5
Rated Voltage1000/5
Rated Current10
Accuracy Class10
Precision Level5
Rated Voltage1200/5
Rated Current20
Accuracy Class20
Precision Level20
Rated Voltage1500/5
Rated Current

Parameter Table 3

<
Parameter CategoryParameter ItemParameter Value
Casing ModelBH-0.66 100 III-
Current Ratio A800/510
1000/510
1200/520
1500/520
2000/530
2500/530
3000/530
800/110
1000/110
1200/120
1500/120
2000/130
2500/130
Rated Output VA1 Class10
0.5 Class10
0.5S Class10
0.2 Class10
0.2S Class5
Through Hole Turns-1
Enclosure and Installation Dimensions--
Height167±1
Width124±1
Depth153±1
-59
-69max
Casing ModelBH-0.66 120 III-
Current Ratio A1000/510
1200/520
1500/520
2000/530
2500/530
3000/530
4000/530
1000/110
1200/120
1500/120
2000/130
2500/130
3000/130
4000/130
Rated Output VA1st class10
0.5th class10
0.5S class10
0.2nd class10
0.2S class5
Through hole turns-1
External dimensions and installation size--
Height183±1
Width140±1
Depth179±1
-52
-71max

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.