BH-0.66 Type II Current Transformer

Product category:
Current transformer
Product code:
P-600
Model:

Function & Use (Application Scenarios)

Power electrical appliances, current transformers are mainly applicable for indoor use, with a maximum equipment voltage of 0.72kV and below, load power factor of 0.8, and rated frequency of 50Hz AC circuits for current and energy measurement or metering. They use busbar fixed or base plate fixed

Surprise on inquiry

Product highlights

  • Convenient installation and maintenance
  • Accurate metering monitoring
  • Engineering Application Compatibility
  • Stable and reliable operation
  • Easy system integration

Model

Main Product Parameters

CategoryCurrent transformerSecondary CategoryCurrent Transformer

Product details

Function and Application

The BH-0.66 II current transformer is used indoors, with a maximum equipment voltage of 0.72kV and below, a load power factor of 0.8, and a rated frequency of 50Hz in AC circuits for current and energy measurement or metering. It can be fixed with a busbar or a base plate. The transformer has a window in the middle, allowing dual busbars or cables to pass through.
Complies with the standard: GB/T 20840.1 &.2.

Detailed Parameters

Parameter Table 1

Parameter CategoryParameter ItemParameter Value
Casing ModelCurrent Ratio A100/5, 150/5, 200/5, 250/5, 300/5, 400/5, 500/5, 600/5, 750/5, 800/5, 150/1, 200/1, 250/1, 300/1, 400/1, 500/1, 600/1
Rated Output VA1 class: 2.5, 0.5S class: 2.5, 0.5S class: 2.5, 0.2S class: 2.5, 0.2S class: 2.5
Through Core Turns1
Outline and Installation DimensionsFigure 1, Figure 2
BH-0.66 40 II
Casing ModelCurrent Ratio A150/5, 200/5, 250/5, 300/5, 400/5, 500/5, 600/5, 750/5, 800/5, 1000/5, 1200/5, 1500/5, 750/5, 800/5, 1000/5, 1200/5, 1500/5, 150/1, 200/1, 250/1, 300/1, 400/1, 500/1, 600/1, 750/1, 800/1, 1000/1, 1200/1
Rated Output VA1 class: 2.5, 0.5S class: 5, 0.5S class: 5, 0.2S class: 5, 0.2S class: 5
Through Core Turns1
Outline and Installation DimensionsFigure 1, Figure 2
BH-0.66 50 II
Note: Products marked with "*" are special custom products.

Parameter Table 2

Parameter CategoryParameter ItemParameter Value
Frame ModelCurrent Ratio A200/5, 250/5, 300/5, 400/5, 500/5, 600/5, 750/5, 800/5, 1000/5, 1200/5, 1500/5*, 2000/5*, 1500/5, 2000/5, 200/1, 250/1, 300/1, 400/1, 500/1, 600/1, 750/1, 800/1, 1000/1, 1200/1, 1500/1, 2000/5*, 2500/5, 2000/5, 2500/5, 600/1, 750/1, 800/1, 1000/1, 1200/1, 1500/1, 2000/1, 2500/1
Rated Output VA1 class: 5, 0.5 class: 2.5, 0.5S class: 5, 0.2 class: 5, 0.2S class: 5
Through Hole Turns1
AppearanceFigure 1, Figure 2
Appearance and Installation Dimensions112max, 31.5, 53±1, 62, 103max (Figure 1), 49max; 129max, 62, 31.5, 53±1, 103max (Figure 2), 49max; 120max, 32.5, 60.5±1, 82, 123max (Figure 1), 48max; 145max, 33.5, 61±1, 82, 123max (Figure 2), 49max
BH-0.66 60 IICurrent Ratio A200/5, 250/5, 300/5, 400/5, 500/5, 600/5, 750/5, 800/5, 1000/5, 1200/5, 1500/5*, 2000/5*, 1500/5, 2000/5, 200/1, 250/1, 300/1, 400/1, 500/1, 600/1, 750/1, 800/1, 1000/1, 1200/1, 1500/1, 2000/5*, 2500/5, 2000/5, 2500/5, 600/1, 750/1, 800/1, 1000/1, 1200/1, 1500/1, 2000/1, 2500/1
Rated Output VA1 class: 5, 0.5 class: 2.5, 0.5S class: 5, 0.2 class: 5, 0.2S class: 5
Through Hole Turns1
AppearanceFigure 1, Figure 2
Appearance and Installation Dimensions112max, 31.5, 53±1, 62, 103max (Figure 1), 49max; 129max, 62, 31.5, 53±1, 103max (Figure 2), 49max; 120max, 32.5, 60.5±1, 82, 123max (Figure 1), 48max; 145max, 33.5, 61±1, 82, 123max (Figure 2), 49max
BH-0.66 80 IICurrent Ratio A200/5, 250/5, 300/5, 400/5, 500/5, 600/5, 750/5, 800/5, 1000/5, 1200/5, 1500/5*, 2000/5*, 2500/5, 2000/5, 2500/5, 600/1, 750/1, 800/1, 1000/1, 1200/1, 1500/1, 2000/1, 2500/1
Rated Output VA1 class: 5, 0.5 class: 2.5, 0.5S class: 5, 0.2 class: 5, 0.2S class: 5
Through Hole Turns1
AppearanceFigure 1, Figure 2
Appearance and Installation Dimensions112max, 31.5, 53±1, 62, 103max (Figure 1), 49max; 129max, 62, 31.5, 53±1, 103max (Figure 2), 49max; 120max, 32.5, 60.5±1, 82, 123max (Figure 1), 48max; 145max, 33.5, 61±1, 82, 123max (Figure 2), 49max

Parameter Table 3

Parameter CategoryParameter ItemParameter Value
Frame ModelCurrent Ratio A800/5A
1000/5
1200/5
1500/5
2000/5
2500/5
3000/5
2500/5*
3000/5*
1000/1
1200/1
1500/1
2000/1
2500/1
3000/1
Rated Output VA1 class 10
0.5 class 10
0.5S class 10
0.2 class 10
0.2S class 5
Through Hole Turns1
Appearance and Installation DimensionsFigure 1
BH-0.66 100 II
Frame ModelCurrent Ratio A1000/5
1200/5
1500/5
2000/5
2500/5
3000/5
4000/5
2500/5*
3000/5*
4000/5*
1000/1
1200/1
1500/1
2000/1
2500/1
3000/1
4000/1
Rated Output VAClass 1 10
0.5 Class 20
0.5S Class 20
0.2 Class 20
0.2S Class 10
Through Hole Turns1
Enclosure and Installation DimensionsFigure 1
BH-0.66 120 II
Note: Products with "*" are special custom products.

Parameter Table 4

Parameter CategoryParameter ItemParameter Value
Frame ModelCurrent Ratio A3000/5
4000/5
5000/5
6000/5
3000/1
4000/1
5000/1
Rated Output VAClass 1: 30, 0.5 Class: 30, 0.5S Class: 20, 0.2 Class: 20, 0.2S Class: 10
Through Hole Turns1
Enclosure and Installation DimensionsSee diagram dimensions
Parameter CategoryParameter ItemParameter Value
Frame ModelCurrent Ratio A4000/5
5000/5
Rated Output VAClass 1: 30, 0.5 Class: 30, 0.5S Class: 20, 0.2 Class: 20, 0.2S Class: 10
Through Hole Turns1
Enclosure and Installation DimensionsSee diagram dimensions
Parameter CategoryParameter ItemParameter Value
Frame ModelCurrent Ratio A4000/5
5000/5
6000/5
Rated Output VAClass 1: 30, 0.5 Class: 30, 0.5S Class: 20, 0.2 Class: 20, 0.2S Class: 10
Through Hole Turns1
Enclosure and Installation DimensionsSee diagram dimensions

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.