HR5 Series Fuse-type Isolator

Product category:
Isolating switch
Product code:
P-690
Model:
HR5

Function & Use (Application Scenarios)

Switching electrical equipment, isolating switches are mainly used for (hereinafter referred to as switches) which are mainly used in distribution circuits and motor circuits with high short-circuit current, with a rated voltage of AC 415V and 690V (45~62Hz), and a nominal heating current up to 630A, as electric

Surprise on inquiry

Product highlights

  • Short-circuit protection capability
  • Reliable isolation protection
  • Engineering Application Compatibility
  • Stable and reliable operation
  • Easy system integration

Model

HR5

Main Product Parameters

CategorySwitchgearSecondary categoryIsolating switch

Product details

Function and Application

The HR5 series fuse-type isolating switch (hereinafter referred to as the switch) is mainly used in distribution circuits and motor circuits with high short-circuit current, with an rated voltage of AC 415V and 690V (45~62Hz), and a nominal thermal current up to 630A. It is used as a power switch, isolating switch, emergency switch, and for circuit protection, but it is generally not used for directly switching single motors.

Detailed Parameters

Parameter Table 1

Parameter CategoryParameter ItemParameter Value
Rated Insulation Voltage1000V
Rated Operating VoltageTwo types: 415V and 690V
Rated Operating Current415V:Five types: 100A, 200A, 250A, 400A, 630A
690V:Five types: 100A, 200A, 250A, 315A, 425A
Switch's ability to connect and disconnect and rated fusing short-circuit currentSee Table 1
Switch's mechanical life2000 times (for 100A, 200A, 250A) and 1000 times (for 400A, 630A)
Switch's electrical life300 times (for 100A) and 200 times (for 200A, 250A, 400A, 630A). The connection and disconnection conditions are according to Table 2.
Auxiliary Switch (Lx19K)Rated operating voltage AC380V
Rated thermal current5A
Rated control capacity300VA
Rated operating voltage Ue VRated thermal current Ith ARated operating current Ie A Usage category Rated connection and disconnection capability Rated limiting short-circuit current
Connection Connection Connection Disconnection Disconnection Disconnection Operation COSΦ Number of cycles
I/Ie U/Ue COSΦ IC/Ie Ur/Ue COSΦ
415100100 AC-23B 10 1.05 0.45 8 1.05 0.45 5 100 0.25 Each once
200200 AC-23B 10 1.05 0.35 8 1.05 0.35 3 100 0.25 Each once
250250 AC-23B 10 1.05 0.35 8 1.05 0.35 3 100 0.25 Each once
400400 AC-23B 10 1.05 0.35 8 1.05 0.35 3 100 0.25 Each once
630630 AC-23B 10 1.05 0.35 8 1.05 0.35 3 100 0.25 Each once
690100100 AC-21B 1.5 1.05 0.65 1.5 1.05 0.65 5 50 0.25 Each once
200200 AC-21B 1.5 1.05 0.65 1.5 1.05 0.65 5 50 0.25 Each once
250250 AC-21B 1.5 1.05 0.65 1.5 1.05 0.65 5 50 0.25 Each once
400315 AC-21B 1.5 1.05 0.65 1.5 1.05 0.65 5 50 0.25 Each once
630425 AC-21B 1.5 1.05 0.65 1.5 1.05 0.65 5 50 0.25 Each once

Parameter Table 2

Parameter CategoryParameter ItemParameter Value
Rated Operating Voltage (V)Usage CategoryConnection I/le U/Ur COSΦ Disconnection Ic/Ie Ur/Ue COSΦ
415AC-23B1 1 0.65 1 1 0.65
690AC-21B1 1 0.8 1 1 0.80
Switch and Fuse Matching Relationship (see Table 3).Switch Nominal Thermal Current (A)Rated Circuit Breaker Model Fuse Current Value (A)
100NT00, RT36-00, NTA00 (only for HR5-100/31)4, 6, 10, 16, 20, 25, 32, 35, 40, 50, 63, 80, 100, 125, 160
200NT1, RT36-1, NTA1 (only for HR5-200/31)80, 100, 125, 160, 200
250NT1, RT36-1, NTA1 (only for HR5-250/31)80, 100, 125, 160, 200, 224, 250
400NT2, RT36-2, NTA2 (only for HR5-400/31)125, 160, 200, 224, 250, 300, 315, 355, 400
630NT3, RT36-3, NTA3 (only for HR5-630/31)315, 355, 400, 425, 500, 630
Note: When the switch is used in engine electrical systems, the rated current of the fuse may be higher than the nominal thermal current of the switch.
Switch Dimensions and Installation Size (see Table 4, Figure 1, Figure 2).ModelRated heating current (A) Size (mm) a b c d e f (mounting hole distance) g h i j
HR5-200、250/31200220±3.60 203±1.45 (62) 193±3.60 342±4.45 130±0.80 190 38 18 25
HR5-200、250/30200220±3.60 203±1.45 62 193±3.60 342±4.45 130±0.80 190 38 18 25
HR5-200、250/20200220±3.60 203±1.45 124 193±3.60 342±4.45 130±0.80 190 38 18 25
HR5-400/31400243±3.60 226±1.45 (70) 209±3.60 358±4.45 130±0.80 215 43 22 30
HR5-400/30400243±3.60 226±1.45 70 209±3.60 358±4.45 130±0.80 215 43 22 30
HR5-400/20400243±3.60 226±1.45 140 209±3.60 358±4.45 130±0.80 215 43 22 30
HR5-630/31630289±4.05 272±1.60 (85) 224±3.60 373±4.45 200±0.925 215 41 16 35
HR5-630/30630289±4.05 272±1.60 85 224±3.60 373±4.45 200±0.925 215 41 16 35
HR5-630/20630289±4.05 272±1.60 170 224±3.60 373±4.45 200±0.925 215 41 16 35

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.