Function & Use (Application Scenarios)

Switching electrical equipment, isolating switches, the main products are this HR6 series of new blue cover fuse-type isolating switch (hereinafter referred to as the switch) is mainly used for rated voltage AC 1000V and below, rated frequency 50Hz, agreed heating current up to 1000A with

Surprise on inquiry

Product highlights

  • Short-circuit protection capability
  • Reliable isolation protection
  • Engineering Application Compatibility
  • Stable and reliable operation
  • Easy system integration

Model

HR6

Main Product Parameters

CategorySwitchgearSecondary CategoryIsolator

Product details

Function and Usage

The HR6 series is a new type of blue cover fuse-type isolator (hereinafter referred to as the switch) mainly used in power distribution circuits and motor circuits with high short-circuit current, with a rated voltage of AC 1000V and below, a rated frequency of 50Hz, and a nominal heat current up to 1000A. It is used as a power switch, isolator, emergency switch, and for circuit protection, but generally not as a direct switch for single motors.

Details Parameters

Parameter Table 1

Parameter CategoryParameter ItemParameter Value
4.1 Switch and Fuse Matching Relationship (see Table 1).nominal heat current (A)100, 160, 250, 400, 630, 800, 1000
Fuse ModelNT00, RT36-00, NGTC00, RS711BC, NT00, RT36-00, NGTC00, RS711BC, NT1, RT36-1, NGTC1, RS711C, NT2, RT36-2, NGTC2, RS712C, NT3, RT36-3, NGTC2, RS712C, CRT4, RT17-1250/1000A (HR6-specific), NT4
Rated Operating Voltage (V)415, 690, 800, 415, 690, 800, 415, 690, 800/1000, 415, 690, 800/1000, 415, 690, 800/1000, 400, 400
Melt Current Value (A)4, 6, 10, 16, 20, 25, 32, 35, 40, 50, 63, 80, 100, 4, 6, 10, 16, 20, 25, 32, 35, 40, 50, 63, 80, 100, 4, 6, 10, 16, 20, 25, 32, 35, 40, 50, 63, 80, 100, 4, 6, 10, 16, 20, 25, 32, 35, 40, 50, 63, 80, 100, 125, 160, 4, 6, 10, 16, 20, 25, 32, 35, 40, 50, 63, 80, 100, 4, 6, 10, 16, 20, 25, 32, 35, 40, 50, 63, 80, 100, 125, 160, 80, 100, 125, 160, 200, 224, 250, 80, 100, 125, 160, 200, 80, 100, 125, 160, 200, 224, 250, 125, 160, 200, 224, 250, 300, 315, 355, 400, 125, 160, 200, 224, 250, 300, 315, 125, 160, 200, 224, 250, 300, 315, 355, 400, 315, 355, 400, 425, 500, 630, 315, 355, 400, 425, 315, 355, 400, 425, 500, 630, 630, 800, 800, 1000

Parameter Table 2

Parameter CategoryParameter ItemParameter Value
ModelHR6-100, HR6-160, HR6-250, HR6-400, HR6-630, HR6-800, HR6-1000
Rated Insulation Voltage (V)1000, 1000, 1000, 1000, 1000, 1000, 1000
nominal heat current (A)d>100, 160, 250, 400, 630, 800, 1000
Rated Operating Current (A)415V (400V for 800A and above)100, 160, 250, 400, 630, 800, 1000
690V100, 160, 250, 315, 425, -, -
800V (AC-21B)100, 100, -, -, -, -, -
800V (AC-20B)/1000V (AC-20B)100, 160, 250, 400, 630, -, -
Rated Make and Break Capacity (A) (at 1.05 Ue)400V/415V, COSΦ=0.35 AC23B (up to 630A), AC22B (above 800A)Make: 1000, 1600, 2500, 4000, 6300, 2400, 3000; Break: 8000, 1280, 2000, 3200, 5040, 2400, 3000
690V, AC22BMake: 300, 480, 750, 1200, 1890, -, -; Break: 300, 480, 750, 1200, 1890, -, -
800V (AC-21B)Make: 150, 240, -, -, -, -, -; Break: 150, 240, -, -, -, -, -
Rated Limiting Short-Circuit Current (kA)50, 50, 50, 50, 50, 100, 100
Installation CategoryIII
The auxiliary switch has an AC rated voltage of 380V, a nominal heat current of 5A, and a usage category of AC-15, with a rated operating power of 300VA.

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.