TDGC, TSGC Series Contact Voltage Regulators

Product category:
Control Transformer
Product code:
P-585
Model:

Function & Use (Application Scenarios)

Power electrical appliances, transformer products are mainly suitable for dry-type air-cooled autotransformer voltage regulator, used in metallurgy, chemical industry, instruments, scientific experiments, etc. Standards: Q/ZT130

Surprise on inquiry

Product highlights

  • Control response is stable
  • Engineering Application Compatibility
  • Stable and reliable operation
  • Easy system integration

Model

Main Product Parameters

CategoryTransformerSecondary CategoryControl transformer

Product details

Function and Use

TDGC, TSGC series contact voltage regulators are dry-type air-cooled autotransformer contact voltage regulators, used in places such as metallurgy, chemical industry, instruments, and scientific experiments. Conforms to the standard: Q/ZT 130.

Details Parameters

/td>
Parameter CategoryParameter ItemParameter Value
4 Main Technical ParametersModelTDGC2-0.2
Rated Capacity (kVA)0.2
Phase Number1
Rated Frequency (Hz)50
Rated Input Voltage (V)220
Output Voltage Range (V)0-250
Rated Output Current (A)0.8
ModelTDGC2-0.5、TDGC2J-0.5
Rated Capacity (kVA)0.5
Phase Number1
Rated Frequency (Hz)50
Rated Input Voltage (V)220
Output Voltage Range (V)0-250
Rated Output Current (A)2
ModelTDGC2-1、TDGC2J-1
Rated Capacity (kVA)1
Phase Number1
Rated Frequency (Hz)50
Rated Input Voltage (V)220
Output Voltage Range (V)0-250
Rated Output Current (A)4
ModelTDGC2-2、TDGC2J-2
Rated Capacity (kVA)2
Phase Number1
Rated Frequency (Hz)50
Rated Input Voltage (V)220
Output Voltage Range (V)0-250
Rated Output Current (A)8
ModelTDGC2-3、TDGC2J-3
Rated Capacity (kVA)3
Phase Number1
Rated Frequency (Hz)50
Rated Input Voltage (V)220
Output Voltage Range (V)0-250
Rated Output Current (A)12
ModelTDGC2-5、TDGC2J-5
Rated Capacity (kVA)5
Phase Number1
Rated Frequency (Hz)50
Rated Input Voltage (V)220
Output Voltage Range (V)0-250
Rated Output Current (A)20
ModelTDGC2J-7
Rated Capacity (kVA)7
Phase Number1
Rated Frequency (Hz)50
Rated Input Voltage (V)220
Output Voltage Range (V)0-250
Rated Output Current (A)28
ModelTDGC2-10、TDGC2J-10
Rated Capacity (kVA)10
Phase Number1
Rated Frequency (Hz)50
Rated Input Voltage (V)220
Output Voltage Range (V)0-250
Rated Output Current (A)40
ModelTDGC2-15、TDGC2J-15
Rated Capacity (kVA)15
Phase Number1
Rated Frequency (Hz)50
Rated Input Voltage (V)220
Output Voltage Range (V)0-250
Rated Output Current (A)60
ModelTDGC2J-20
Rated Capacity (kVA)20
Phase Number1
Rated Frequency (Hz)50
Rated Input Voltage (V)220
Output Voltage Range (V)0-250
Rated Output Current (A)80
ModelTDGC2J-30
Rated Capacity (kVA)30
Phase Number1
1
Rated frequency (Hz)50
Rated input voltage (V)220
Voltage output range (V)0-250
Rated output current (A)120
ModelTDGC2J-40
Rated capacity (kVA)40
Phase number1
Rated frequency (Hz)50
Rated input voltage (V)220
Voltage output range (V)0-250
Rated output current (A)160
ModelTSGC2-1.5
Rated capacity (kVA)1.5
Phase number3
Rated frequency (Hz)50
Rated input voltage (V)380
Voltage output range (V)0-430
Rated output current (A)2
ModelTSGC2-3、TSGC2J-3
Rated capacity (kVA)3
Phase number3
Rated frequency (Hz)50
Rated input voltage (V)380
Voltage output range (V)0-430
Rated output current (A)4
ModelTSGC2-6、TSGC2J-6
Rated capacity (kVA)6
Phase number3
Rated frequency (Hz)50
Rated input voltage (V)380
Voltage output range (V)0-430
Rated output current (A)8
ModelTSGC2-9、TSGC2J-9
Rated capacity (kVA)9
Phase number3
Rated frequency (Hz)50
Rated input voltage (V)380
Voltage output range (V)0-430
Rated output current (A)12
ModelTSGC2-15、TSGC2J-15
Rated capacity (kVA)15
Phase number3
Rated frequency (Hz)50
Rated input voltage (V)380
Voltage output range (V)0-430
Rated output current (A)20
ModelTSGC2J-20
Rated capacity (kVA)20
Phase number3
Rated frequency (Hz)50
Rated input voltage (V)380
Voltage output range (V)0-430
Rated output current (A)27
ModelTSGC2J-30
Rated capacity (kVA)30
Phase number3

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.